Characteristics
|
MON-EA8
|
|
Number of measurement channels
|
8 individually configurable channels
|
|
Sensors/configurable measurement technologies
|
-transducers with voltage output;
-transducers with current output;
-tensometric full bridge or half bridge;
-inductive transducers LVDT;
-potentiometric and resistive transducers;
-thermoresistances PT100, PT500, PT1000;
-thermistors
|
|
Measurement ranges
|
|
Voltage input
|
Measurement voltage range: ±10V;
Voltage resolution: 0.05 mV;
|
|
Current input
|
Measurement current range: 0-20mA, 4-20mA, 0-10mA;
Current resolution: 0.05 mA;
|
|
Resistance type input
|
Measurement resistance range: 0-1kΩ, 0-5kΩ, 0-10kΩ;
Resistance resolution: 0.1 mΩ;
|
|
Thermoresistance type input
|
Types of RTD: PT100, PT500, PT1000;
Temperature resolution: 0.1°C;
|
|
Tensometric bridge type input
|
Tensometric bridge: with resistances of 120 Ω / 350 Ω
Sensitivity: 1mV/V, 2mV/V, 5mV/V
|
|
LVDT bridge input
|
Excitation frequency: max. 5 kHz
Excitation voltage: max. 10Vvv
|
|
Provides power for active sensors
|
For resistive sensors, tensometric bridges and LVDT transducers |
| Sampling frequency |
Max. 8kS/s
|
|
Supply
|
PoE / 12Vcc / 24Vca / Max. 10W
|
|
Communication
|
Ethernet, IEEE 1588
|
|
Operating temperature range
|
0 °C – 40 °C
|
|
Storage temperature range
|
-40 °C ... +70 °C
|
|
Protection degree
|
IP20
|
|
Dimensions L x l x H
|
295 x 165 x 115 mm
|